ARO-2000

For large size machine tools and central systems!

  • The ARO multi-stage oil mist collectors separate mist in progressive stages reducing the potential of plugging.
  • Filters are depth loading and designed to drain, suitable for 24/7 operation.
  • Cross-flow filter design, air flow is horizontal, oil drains vertical down.
  • Ideal for high pressure coolant and oil.
  • Removes mist, smoke and bacteria.
  • Unique 1st and 2nd separation stages.
  • Optional On-Line Cleaning system.

View the Specifications PDF

Description

Separation Stages:

The innovative 1st stage `ME` Mechanical Element separates up to 90% of the oil mist and swarf. The smooth metal surfaces quickly drains fluid back to the sump.

The 2nd stage `AG` Agglomerator filter is very unique, manufactured in layers of stainless steel wire mesh weaved with oil attracting fibers. Efficiency is high as the air travels through a bed of coarse and fine fibers at low velocity. The ÀG media is very durable, lasting 10 – 15 years. Can be washed. Used only for coolant applications.

The 3rd stage `CM` Coolant Mist filter is depth loading fiber bed filter that capture small mist particles. Typical life 1 – 3 years. For oil applications, 2nd+3rd stage `OM` Oil Mist pack is an unique two stage depth loading fiber bed filter. The `OM` can be supplied in 3 efficiencies. Typical life 1 – 3 years.

Final 4th stage `HF` HEPA filter captures sub-micron mist, smoke and bacteria. Efficiency 95% @ 0.3 µm is standard, optional 99.9% @ 0.3 µm. Typical life 2 – 4 years HEPA filter is made with exclusive heavy duty filter media, no other product holds as much or lasts as long.

Additional information

Air Flow

1800 – 2200 cfm

Machine Tool Enclosure

Up to 900 ft³

Filter Pressure, Max

3.5” wg

Motor (Motorized Impeller)

3 hp

Voltage (amps)

230/3/60 (5.5)
460/3/60 (2.8)
575/3/60 (2.2)

Temperature (Max)

160ºF / 70º

Weight

390 lbs

Length

25” frame, 50” overall

Width

25”

Height

49”

Inlet Connection

12” Ø

Sound

71 dB(A)

Clean Air Measurement

HEPA filter 95% < 0.050 mg/m³
HEPA filter 99.9% < 0.010 mg/m³